Spectroscopic and radiochemistry solutions for laboratory, field, and personnel applications with experts located throughout the world to provide local support and address any measurement needs.
With Apex-Alpha software, the complete status of your alpha spectrometers is available at a glance. Click – and find all the batches waiting to be counted.
The Series 6LB counter uses the novel “system on slide” concept where the shield is fixed in place while the entire sample changer and detector smoothly slides out and away from it.
The iMatic system is a firmware based, automatic, low background, gas-less alpha/beta counter designed specifically for the analysis of air filters and smear or swipe samples.
The Series 5 LB5500 low background alpha /beta counter offers a completely integrated, computer controlled system for maximum flexibility in analyzing larger size samples.
Designed for the way samples are counted in production laboratories, thereby making gross alpha/beta sample analysis and associated quality assurance and data management tasks fast and efficient.
CosmicGuard device is a simple add-on to any new or existing High Purity Germanium (HPGe) counting system that includes a Lynx® Digital Signal Analyzer and Genie™ 2000 or Apex-Gamma™ spectroscopy software.
The Cryo-Cycle II cryostat is described as a “hybrid” cryostat because it combines the advantages of electric cooling with the reliability of liquid nitrogen.
Germanium detectors are semiconductor diodes having a p-i-n structure in which the intrinsic (i) region is sensitive to ionizing radiation, particularly x rays and gamma rays.
The InSpector 1000 analyzer is a high-performance, handheld NaI spectrometer for use primarily in first responder, customs, homeland security, and health-physics applications.
This ISOCS (In Situ Object Counting System) Shield has been designed as the optimum in convenience and functionality for in situ gamma spectroscopy with a germanium detector.
The CSM-GR1 Continuous Spectroscopic Monitor is a very small, yet powerful, in situ measurement system based on standard and well-established Canberra™ gamma spectroscopy components.
Designed for both laboratory and field use, this one compact unit contains a high-voltage power supply (HVPS), preamplifier and a full-featured digital MCA.
The DSA-LX® analyzer offers cost effective, no-compromise DSP-quality spectroscopy in a very compact package. It is operated through Genie 2000 spectroscopy software which provides the user with ultimate flexibility.
The ACCUSCAN II counter is a high resolution, stand-up whole body counter. It is designed to identify and quantify radionuclides with energies between 100 keV and 1336 keV in complicated combinations.
The FASTSCAN system uses large area sodium iodide detectors and Apex-InVivo™ and Genie™ software to achieve low minimum detectable activities with count times as fast as one minute.
An advanced in vivo counting system and a comprehensive management tool that helps monitor and maintain your counters as well as keep track of all the results they generate.
In the CLOVER detector assembly, the crystals are held on a minimized crystal holder to reduce the quantity of material surrounding the crystals and to improve peak to background ratio.
Silicon Lithium X-Ray Detectors are the heart of solid state x-ray spectroscopy systems. These detectors, which are p-i-n devices formed by lithium compensation or drifting of p-type silicon, are the result of some of the most carefully controlled manufacturing processes in existence.
EGPS series is the best choice for X or gamma ray measurements in many applications such as Physics or Astrophysics experiments as well as non invasive detection or medical application.
The broad-band x-ray flux from synchrotron radiation sources has revitalized the relatively old experimental technique known as x-ray absorption spectrometry.
Segmentation techniques fit with all crystal designs: circular, rectangular, etc. ESLX-S detectors in a unique cryostat, offer high energy X-ray absorption or imaging capabilities.
Encapsulation drastically enhances the germanium detector reliability. This technology is key for many applications, particularly in space, and especially if associated with Ultra High Vacuum.
SDD using the proprietary PIPS® technology is a spectroscopy sub-system sensitive to X rays and low-energy gamma rays. It comprises a hermetically sealed silicon drift detector (SDD) element with a low noise FET assembly and a Peltier cooler.